Tk Source Code

View Ticket
Login
Ticket UUID: 3529885
Title: negative resolution confuses scale widget
Type: Bug Version: obsolete: 8.6b2
Submitter: gregcouch Created on: 2012-05-26 02:27:31
Subsystem: 15. [scale] Assigned To: fvogel
Priority: 6 Severity: Minor
Status: Closed Last Modified: 2014-11-07 14:21:27
Resolution: Fixed Closed By: dgp
    Closed on: 2014-11-07 14:21:27
Description:
A negative resolution is used to indicate that the value should not be rounded, but then clicking in the trough causes the slider to move away from the mouse pointer instead of towards it.
User Comments: dgp added on 2014-11-07 14:21:27:
merged to release branches

fvogel added on 2014-11-06 21:48:43:
Test added in the scale test suite.
Fails before the patch, succeeds with the patch.

fvogel added on 2014-10-30 21:58:20:
Thanks for the patch. I have understood what it does and it looks correct to me.

Running the following script and playing with mouse clicks in the through areas confirms the problem is fixed:

  scale .s1 -from 0 -to 100 -digits 5 -resolution 1
  scale .s2 -from 0 -to 100 -digits 5 -resolution -1
  scale .s3 -from 100 -to 0 -digits 5 -resolution 1
  scale .s4 -from 100 -to 0 -digits 5 -resolution -1
  pack .s1 .s2 .s3 .s4 -side left

Patch committed to branch bug-3529885fff

gregcouch added on 2012-05-26 09:27:31:

File Added - 444490: tk8.6-scale.patch

Attachments: