Ticket UUID: e67618079ff8e8c6b3b4c92fd9b59fb0cf117595
Title: Win rdp forwarded serial port: setting -sysbuffer gives "can't setup comm buffers: invalid argument"
Type: Bug Created on: 2020-04-22 13:39:55
Submitter: oehhar Assigned to: jan.nijtmans
Subsystem: 27. Channel Types Severity: Minor
Priority: 5 Medium Last modified: 2020-04-22 14:37:36
Status: Open Closed by: nobody
Resolution: None Closed on:
Version: 8.6.10
Description:

A Windows 10 computer screen is forewarded to a ThinClient (Linux) via rdp protocoll. A physical serial port on the Thin Client is forewarded to the WIndows 10 computer by the same rdp connection. Wish8.6.10 is started on the Windows computer:

% set h [open COM2 RDWR]
file3903678
% fconfigure $h -mode 19200,n,8,1 -buffering full -blocking 0 -translation binary
% fconfigure $h -sysbuffer 32768
can't setup comm buffers: invalid argument
% fconfigure $h
-blocking 0 -buffering full -buffersize 32768 -encoding binary -eofchar {{} {}}\
-translation {lf lf} -mode 19200,n,8,1 -pollinterval 10 -sysbuffer {4096 4096} -xchar { }
% fconfigure $h -sysbuffer 4096
can't set comm state: no such device

Setting the option "-sysbuffer" for the forewarded serial port causes different error messages:

  • 32768: "can't setup comm buffers: invalid argument".
  • 4096 (the default value): "can't set comm state: no such device"

Thank you all, Harald

User Comments:
jan.nijtmans added on 2020-04-22 14:14:17:

Please try: [8b444e9115ef688c]

According to Microsoft's documentation, SetCommState() has some restrictions. This might help, but I cannot test it.


oehhar added on 2020-04-22 14:27:38:

Light speed, will test.

To add, the option "-handshake" also fails in this situation. All other options are ok.

Thank you, Harald


oehhar added on 2020-04-22 14:37:36:

Sorry, but it is still the same error.