| Ticket UUID: | 1ae976e237cf0a4d040de9435ce0554a8c8c7606 | ||
| Title: | Compiled [clock clicks -mi] returns microseconds instead of an ambiguous option error | ||
| Type: | Bug | Created on: | 2026-10-12 20:32:40 |
| Submitter: | serhiy.storchaka | Assigned to: | jan.nijtmans |
| Subsystem: | 47. Bytecode Compiler | Severity: | Minor |
| Priority: | 5 Medium | Last modified: | 2026-10-13 12:15:42 |
| Status: | Closed | Closed by: | jan.nijtmans |
| Resolution: | Fixed | Closed on: | 2026-10-13 12:15:42 |
| Version: | 9.1.0 | ||
| Description: | ||||
|
proc p {} {clock clicks -mi}
p
9.0 compiles the option only if it is at least 4 characters long, so it gives
the error in both cases. [507b920e63] (TIP 720) replaced that check with
Proposed fix in branch compile-clock-clicks-ambiguous: require 4 characters again. Tests clock-33.7.1 and clock-33.7.2. | ||||
| User Comments: | ||||
jan.nijtmans added on 2026-10-13 12:15:42:
Fixed in [88c6ad4c756c8244|trunk] Many thanks! | ||||